{"id":4903,"date":"2026-05-05T15:42:44","date_gmt":"2026-05-05T07:42:44","guid":{"rendered":"https:\/\/wp.dentalcncs.com\/?p=4903"},"modified":"2026-05-09T15:56:55","modified_gmt":"2026-05-09T07:56:55","slug":"ursachen-fur-zirkonoxidkronenbruche-nach-dem-sintern-in-der-zahntechnischen-laborverarbeitung","status":"publish","type":"post","link":"https:\/\/www.dentalcncs.com\/de\/blog\/causes-of-zirconia-crown-fracture-after-sintering-in-dental-laboratory-processing\/","title":{"rendered":"Ursachen f\u00fcr Zirkonoxidkronenbr\u00fcche nach dem Sintern in der zahntechnischen Laborverarbeitung"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4903\" class=\"elementor elementor-4903\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a2cf95 e-flex e-con-boxed e-con e-parent\" data-id=\"a2cf95\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-486fd081 elementor-widget elementor-widget-text-editor\" data-id=\"486fd081\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p class=\"has-text-align-center\" style=\"text-align: left;\">In s\u00fcdamerikanischen Dentallaboren \u2013 insbesondere in Brasilien, Chile, Mexiko und Argentinien \u2013<strong>Bruch einer Zirkonoxidkrone nach dem Sintern<\/strong> bleibt eine h\u00e4ufige Herausforderung, die die Konsistenz von Restaurierungen und Neuauflagen beeintr\u00e4chtigt. Das Problem ist besonders deutlich zu erkennen bei <strong>Zahnersatz f\u00fcr den gesamten Zahnbogen<\/strong> und bei der Herstellung von mehrteiligen Br\u00fccken, wo Br\u00fcche h\u00e4ufig in der N\u00e4he von Verbindungsstellen, R\u00e4ndern oder tragenden Bereichen auftreten.<\/p>\n<p style=\"text-align: left;\"><!-- \/wp:paragraph --><!-- wp:paragraph {\"align\":\"center\"} --><\/p>\n<p class=\"has-text-align-center\" style=\"text-align: left;\">In vielen F\u00e4llen wird die Rissbildung nicht durch einen einzigen Faktor verursacht. Stattdessen ist sie das Ergebnis von <strong>Materialauswahl, CAD-Konstruktion, Fr\u00e4sbedingungen und Sinterkompatibilit\u00e4t arbeiten zusammen<\/strong>. Dieser Artikel untersucht typische Frakturf\u00e4lle und praktische CAD\/CAM-Optimierungsstrategien.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<p class=\"wp-block-heading\"><strong>H\u00e4ufige F\u00e4lle von Rissen in Zirkonoxidkronen<\/strong><\/p>\n<p><!-- \/wp:heading --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\" style=\"text-align: center;\"><span style=\"color: #008ed4;\">Fall 1: Verbindungsstellenbr\u00fcche bei Vollbogenbr\u00fccken<\/span><\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Bei weitgespannten Restaurationen mit d\u00fcnnen Verbindungsstellen kommt es w\u00e4hrend des Sinterprozesses vermehrt zu thermischen Spannungskonzentrationen.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><strong>Typische Ursachen sind:<\/strong><\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>\n<p>Mangelhafte Steckerkonstruktion<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p>Ungenaue Schwundkompensation<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p>Materialfestigkeitsunterschiede in den hinteren Bereichen<\/p>\n<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><!-- wp:paragraph --><\/p>\n<p>F\u00fcr die hinteren Bereiche ist in der Regel eine st\u00e4rkere Zirkonoxid-Unterst\u00fctzung erforderlich.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\" style=\"text-align: center;\"><span style=\"color: #008ed4;\">Fall 2: Randabsplitterungen und Mikrorisse<\/span><\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Kleinere Risse, die beim Fr\u00e4sen entstehen, k\u00f6nnen sich nach dem Sintern ausdehnen.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p><strong>H\u00e4ufige Ursachen sind:<\/strong><\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>\n<p>Abgenutzte Fr\u00e4sstifte<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p>Inkonsistente Materialstruktur<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p>D\u00fcnne Restaurationsr\u00e4nder<\/p>\n<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><!-- wp:paragraph --><\/p>\n<p>Diese Probleme treten h\u00e4ufig bei der Herstellung von Pr\u00e4zisionskronen auf.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:image {\"id\":4904,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} --><\/p>\n<p class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"635\" height=\"373\" class=\"wp-image-4904 aligncenter\" src=\"https:\/\/wp.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png\" alt=\"\" srcset=\"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png 635w, https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009-300x176.png 300w, https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009-18x12.png 18w\" sizes=\"(max-width: 635px) 100vw, 635px\" \/><\/p>\n<p><!-- \/wp:image --><!-- wp:heading --><\/p>\n<p class=\"wp-block-heading\"><strong>Wie Materialeigenschaften die Sinterstabilit\u00e4t beeinflussen<\/strong><\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Bei Zirkonoxid-Vollzahnrestaurationen hat die Materialleistung einen starken Einfluss auf das Endergebnis.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:paragraph --><\/p>\n<p>Zu den wichtigsten technischen Indikatoren geh\u00f6ren h\u00e4ufig:<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>\n<p><strong>Biegefestigkeit von 700\u20131200 MPa<\/strong><\/p>\n<p>Unterst\u00fctzt unterschiedliche okklusale Anforderungen bei Front- und Seitenzahnrestaurationen.<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p><strong>15-schichtige Gradientenstruktur<\/strong><\/p>\n<p>Hilft dabei, nat\u00fcrliche Zahn\u00fcberg\u00e4nge zu simulieren und die Spannungsverteilung zu verbessern.<\/p>\n<\/li>\n<!-- \/wp:list-item --><!-- wp:list-item -->\n<li>\n<p><strong>43%\u201357% Transparenzgradient<\/strong><\/p>\n<p>Verbessert das nat\u00fcrliche Erscheinungsbild und erh\u00e4lt gleichzeitig die mehrschichtige \u00c4sthetik.<\/p>\n<\/li>\n<!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><!-- wp:paragraph --><\/p>\n<p>S\u00fcdamerikanische Labore evaluieren zunehmend <strong>Sinterkonsistenz<\/strong>, nicht nur die Farbanpassung.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:image {\"id\":4905,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} --><\/p>\n<p class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"522\" height=\"523\" class=\"wp-image-4905 aligncenter\" src=\"https:\/\/wp.dentalcncs.com\/wp-content\/uploads\/2026\/05\/\u5c4f\u5e55\u622a\u56fe-2026-03-19-154322.png\" alt=\"\" srcset=\"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/\u5c4f\u5e55\u622a\u56fe-2026-03-19-154322.png 522w, https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/\u5c4f\u5e55\u622a\u56fe-2026-03-19-154322-300x300.png 300w, https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/\u5c4f\u5e55\u622a\u56fe-2026-03-19-154322-150x150.png 150w, https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/\u5c4f\u5e55\u622a\u56fe-2026-03-19-154322-12x12.png 12w\" sizes=\"(max-width: 522px) 100vw, 522px\" \/><\/p>\n<p><!-- \/wp:image --><!-- wp:heading --><\/p>\n<p class=\"wp-block-heading\"><strong>CAD\/CAM-Optimierungsstrategien<\/strong><\/p>\n<p><!-- \/wp:heading --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\">1. Verbesserung der Br\u00fcckenkonstruktion<\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Vermeiden Sie \u00fcberm\u00e4\u00dfige Auslegerl\u00e4ngen und achten Sie auf eine ausgewogene Verbinderdicke.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\">2. Sinterprofile anpassen<\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Unterschiedliche Zirkonoxidsysteme erfordern spezifische Heiz- und K\u00fchlparameter.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\">3. W\u00e4hlen Sie mehrschichtiges Zirkonoxid.<\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Gradienten-Zirkonoxidstrukturen verbessern die Lastverteilung bei vollst\u00e4ndigen Zahnbogenrestaurationen.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading {\"level\":3} --><\/p>\n<p class=\"wp-block-heading\">4. Zustand des Fr\u00e4sers \u00fcberwachen<\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Werkzeugverschlei\u00df kann die Kantenspannung erh\u00f6hen und eine Rissausbreitung nach dem Sintern ausl\u00f6sen.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<p class=\"wp-block-heading\"><strong>Brancheneinblick: Neue Trends in s\u00fcdamerikanischen Dentallaboren<\/strong><\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Mit dem Wachstum der digitalen Zahnmedizin in S\u00fcdamerika verlagern die Labore ihren Fokus von der reinen Produktionsgeschwindigkeit hin zur Priorisierung von <strong>Materialstabilit\u00e4t und langfristige Prozesskonsistenz<\/strong>.<\/p>\n<p><!-- \/wp:paragraph --><!-- wp:heading --><\/p>\n<p class=\"wp-block-heading\"><strong>Abschluss<\/strong><\/p>\n<p><!-- \/wp:heading --><!-- wp:paragraph --><\/p>\n<p>Risse in Zirkonoxidkronen nach dem Sintern sind in der Regel die Folge von <strong>mehrere miteinander verbundene Faktoren<\/strong>, Dies umfasst Materialeigenschaften, Konstruktionslogik und W\u00e4rmebehandlung. Bei vollst\u00e4ndigen Zahnbogenrestaurationen kann die Auswahl von mehrschichtigem Zirkonoxid mit stabilen Festigkeitsgradienten und die Optimierung von CAD\/CAM-Arbeitsabl\u00e4ufen dazu beitragen, das Bruchrisiko zu verringern und die Zuverl\u00e4ssigkeit der Restauration zu verbessern.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div>","protected":false},"excerpt":{"rendered":"<p>Across South American dental laboratories\u2014particularly in Brazil, Chile, Mexico, and Argentina\u2014zirconia crown fracture after sintering remains a common challenge affecting [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4904,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_eb_attr":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[7],"tags":[],"class_list":["post-4903","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dentalcncs.com\/de\/blog\/ursachen-fur-zirkonoxidkronenbruche-nach-dem-sintern-in-der-zahntechnischen-laborverarbeitung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\" \/>\n<meta property=\"og:description\" content=\"Across South American dental laboratories\u2014particularly in Brazil, Chile, Mexico, and Argentina\u2014zirconia crown fracture after sintering remains a common challenge affecting [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dentalcncs.com\/de\/blog\/ursachen-fur-zirkonoxidkronenbruche-nach-dem-sintern-in-der-zahntechnischen-laborverarbeitung\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-05T07:42:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-09T07:56:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png\" \/>\n\t<meta property=\"og:image:width\" content=\"635\" \/>\n\t<meta property=\"og:image:height\" content=\"373\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"kaka.cao@yucera.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"kaka.cao@yucera.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/\"},\"author\":{\"name\":\"kaka.cao@yucera.com\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#\\\/schema\\\/person\\\/76d826751ab8c3caeca7ea258ead806d\"},\"headline\":\"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing\",\"datePublished\":\"2026-05-05T07:42:44+00:00\",\"dateModified\":\"2026-05-09T07:56:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/\"},\"wordCount\":390,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/043009.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/\",\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/\",\"name\":\"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/043009.png\",\"datePublished\":\"2026-05-05T07:42:44+00:00\",\"dateModified\":\"2026-05-09T07:56:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/043009.png\",\"contentUrl\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/043009.png\",\"width\":635,\"height\":373},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/pt\\\/blog\\\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dentalcncs.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/\",\"name\":\"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dentalcncs.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#organization\",\"name\":\"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\",\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/\u5fae\u4fe1\u56fe\u7247_20220713142447-1-scaled.png\",\"contentUrl\":\"https:\\\/\\\/www.dentalcncs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/\u5fae\u4fe1\u56fe\u7247_20220713142447-1-scaled.png\",\"width\":2560,\"height\":515,\"caption\":\"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.dentalcncs.com\\\/#\\\/schema\\\/person\\\/76d826751ab8c3caeca7ea258ead806d\",\"name\":\"kaka.cao@yucera.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g\",\"caption\":\"kaka.cao@yucera.com\"},\"sameAs\":[\"http:\\\/\\\/47.77.229.231\"],\"url\":\"https:\\\/\\\/www.dentalcncs.com\\\/de\\\/author\\\/kaka-caoyucera-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dentalcncs.com\/de\/blog\/ursachen-fur-zirkonoxidkronenbruche-nach-dem-sintern-in-der-zahntechnischen-laborverarbeitung\/","og_locale":"de_DE","og_type":"article","og_title":"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","og_description":"Across South American dental laboratories\u2014particularly in Brazil, Chile, Mexico, and Argentina\u2014zirconia crown fracture after sintering remains a common challenge affecting [&hellip;]","og_url":"https:\/\/www.dentalcncs.com\/de\/blog\/ursachen-fur-zirkonoxidkronenbruche-nach-dem-sintern-in-der-zahntechnischen-laborverarbeitung\/","og_site_name":"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","article_published_time":"2026-05-05T07:42:44+00:00","article_modified_time":"2026-05-09T07:56:55+00:00","og_image":[{"width":635,"height":373,"url":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png","type":"image\/png"}],"author":"kaka.cao@yucera.com","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"kaka.cao@yucera.com","Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#article","isPartOf":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/"},"author":{"name":"kaka.cao@yucera.com","@id":"https:\/\/www.dentalcncs.com\/#\/schema\/person\/76d826751ab8c3caeca7ea258ead806d"},"headline":"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing","datePublished":"2026-05-05T07:42:44+00:00","dateModified":"2026-05-09T07:56:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/"},"wordCount":390,"commentCount":0,"publisher":{"@id":"https:\/\/www.dentalcncs.com\/#organization"},"image":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png","articleSection":["Blog"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/","url":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/","name":"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing - \u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","isPartOf":{"@id":"https:\/\/www.dentalcncs.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#primaryimage"},"image":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png","datePublished":"2026-05-05T07:42:44+00:00","dateModified":"2026-05-09T07:56:55+00:00","breadcrumb":{"@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#primaryimage","url":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png","contentUrl":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/05\/043009.png","width":635,"height":373},{"@type":"BreadcrumbList","@id":"https:\/\/www.dentalcncs.com\/pt\/blog\/causas-de-fratura-de-coroas-de-zirconia-apos-sinterizacao-em-laboratorio-de-protese-dentaria\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dentalcncs.com\/"},{"@type":"ListItem","position":2,"name":"Causes of Zirconia Crown Fracture After Sintering in Dental Laboratory Processing"}]},{"@type":"WebSite","@id":"https:\/\/www.dentalcncs.com\/#website","url":"https:\/\/www.dentalcncs.com\/","name":"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","description":"","publisher":{"@id":"https:\/\/www.dentalcncs.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dentalcncs.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.dentalcncs.com\/#organization","name":"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9","url":"https:\/\/www.dentalcncs.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dentalcncs.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20220713142447-1-scaled.png","contentUrl":"https:\/\/www.dentalcncs.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20220713142447-1-scaled.png","width":2560,"height":515,"caption":"\u7b2c\u4e00\u9875\u6d4b\u8bd5\u7f51\u7ad9"},"image":{"@id":"https:\/\/www.dentalcncs.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.dentalcncs.com\/#\/schema\/person\/76d826751ab8c3caeca7ea258ead806d","name":"kaka.cao@yucera.com","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3cb476ecf6044c1eaffc81f857d848a1e355efc57db659d3a3dc812731887612?s=96&d=mm&r=g","caption":"kaka.cao@yucera.com"},"sameAs":["http:\/\/47.77.229.231"],"url":"https:\/\/www.dentalcncs.com\/de\/author\/kaka-caoyucera-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/posts\/4903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/comments?post=4903"}],"version-history":[{"count":7,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/posts\/4903\/revisions"}],"predecessor-version":[{"id":4916,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/posts\/4903\/revisions\/4916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/media\/4904"}],"wp:attachment":[{"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/media?parent=4903"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/categories?post=4903"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dentalcncs.com\/de\/wp-json\/wp\/v2\/tags?post=4903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}